5199 views | 2 answers | The size of beam and slab , column should be depend on many factor not only the span of structure. you should consider the load on that structure. in your case i don't think 12" beam depth is enough. at least you should take 1.5' depth because your span is more that 5 mt. . |
|
2272 views | 3 answers | why we are providing main rod up and distributed rod down in cantilever slab?. |
3433 views | 1 answers | Dear sir,Here i am working one Temple construction of having 115'X115' hall. We constructed wall that is cavity wall. and also finished roof. please give me advice about maintaining good sound quality in hall. i means free from Echo and silence. revibrating. please is that cavity wall help sound? . |
3986 views | 2 answers | Please kindly help me to decide the labor rate of R.C.C
beam and slab for my project.
Work detail
Beam size 3.5’ X1.5’ X 80’
Slab: 44’X80’
The height of building is 43’ level.
Our contractor Rate as below
Beam: 450rs/sqft
Slab: 350rs/sqft.
What is the current basic rate for
Centering /shuttering
Reinforcement 25mm
20mm and 12mm for stirrup.
Slab : 8mm dia. |
3561 views | 4 answers | Dear Sir,I am handling a construction of new temple, not from starting. i handle that from ground floor and That work is given for two local contractor as an item wise labour contract. they quoted the rate of R.C.C column and beam in unit sqft and measuring the surface area of beam and column(including steel and centering work). For eg: column having 24"X24" of height 4'. they measuring 2+2+2+2= . |
2231 views | 1 answers | Here i have to Constructed the GODOWN 160'X55' having metalic sheet truss roof. the Column span is max 16ft . there is no column at cemter. please what is the column size and also reinforcement required. Also what is the foundation sizze required....Here my contractor given 9"X15" cloumn size and also 4mo's 16 dia +4 no's 12dia reinforcement for column. foundation 4'X5'. |
3115 views | 2 answers | Dear sir, or madamI want to constructed the Hip Types rcc picth roof for my 35'X45' size single floor building. how i have to construct the roof. give me an idea. Here i upload my rough plan. . |
2332 views | 5 answers | what is the best method to tiling the
outside or exterior. we need that tiles should be free from sun effect in future. using adhesive only after rough plastering or grout? we need to tile 8 floor
height. if any good adhesive recommend me.. |
1815 views | 3 answers | Dear sir,I am thank for your valuable respond for all my problem. here i have water leakage problem for few old existing R.C.C building. here we done my zicosil and also trape creat chemical treatment but that does not work well. Now i thought to laid 2" screed concrete with untra techi. water proof chemical. as per my knowledge that better than those water proof chemical coating. please can you . |
2304 views | 1 answers | Dear allHere i want to know best method of water proofing for existing building which have leakage problem and also thin crack on slab. Actually we did many time chemical treatment like zicosil and trape creat both of this does not work.Now as per my idea i thought to do screed concrete with ultra-techi water proofing chemical. if any better idea please share me as soon as possible. specially i . |