4089 views | 1 answers | Sir, what is the RCC lintel standard thickness and number of iron rods and gauge for a two story house with load bearing walls?. |
|
3244 views | 1 answers | As seen in the attached picture, the plan lists different area measurements under different titles. So, please suggest which area measurement should be used to calculate total cost based on per/sqft rate given by the contractor. . |
23802 views | 2 answers | I am confused about whether to choose PPC or PSC cement for RCC roof....Planning to buy ultratech brand but which type to choose. Please suggest.. |
4995 views | 1 answers | I am confused about choosing concrete door frames vs wooden door frames. There are thick concrete door frames even for front door with good appearance. So, I need experts opinion about the reliability and lifetime of concrete door frames vs wooden frames.. |
1382 views | 1 answers | I have filled the rubble foundation using quarry slurry which is of low cost but not strong/dense as earth filling. So, what is the safest thickness of floor concreting above it? Should I use steel bars as reinforcement in floor concreting? . |
1322 views | 1 answers | I am planning to avoid sunshade and extend the main roof 2.5ft and then bend downwards 1ft at right angle like L. So, would it adversely affect the air circulation through air holes since those will be blocked by the 1f downward extension of main slab even though there would be a distance of 2.5ft between both? If yes, is there any idea to solve the issue?. |
5154 views | 1 answers | My contractor told me that fixing wooden door frames after the construction of wall and rcc roof but before the plastering work will save it from possible damages during construction phase. But some others of the opinion that fixing door frames at the initial stage of construction is easy and will give good finish. So, please help. Is there any drawback in fixing door frames after the wall and roo. |
994 views | 1 answers | Is it possible to fix compound wall iron gate weighing around 150kg on a 8"x8" rcc pillar? We can not give extra width for pillar footing due to space limitations. If possible please also tell me how deep the pillar must go below the ground level.. |
1619 views | 1 answers | I want to install washbasin, Extended wall mount closet and overhead shower with wall mount panel in both bathrooms attached to bedroom. Just confused about the position of shower ie. Washbasin, Shower, closet OR Wash basin, Closet, Shower. Other layouts/suggestions are also welcome!. |
3062 views | 1 answers | painter suggests same oil primer and paint which is used for iron bars, but when product details recommends it only on metal surfaces. Painter says the cement primer if used will peel off easily. So, please suggest a good type and brand primer and paint for concrete window and door frames. . |